国产精品女人性满足免费视频,亚洲一区二区三区四,日本激情视频一区二区三区,免费久久香蕉网站

  • <strong id="wl7av"><font id="wl7av"><dl id="wl7av"></dl></font></strong>

    <pre id="wl7av"><tt id="wl7av"></tt></pre>
  • <object id="wl7av"></object>

  • <sup id="wl7av"></sup><address id="wl7av"><var id="wl7av"></var></address>
    <b id="wl7av"><source id="wl7av"><table id="wl7av"></table></source></b>

    search
    產(chǎn)品圖片
    產(chǎn)品圖片
    產(chǎn)品圖片

    JMHVS-1-XYZ

    Brand:

    Mitech

    Model:

    Measuring range:

    5-2500HV

    Resolution Accuracy:

    Communication storage:

    Working time:

    Main unit weight:

    Dimensions:

    Package dimensions:

    61*53*78cm

    Total weight:

    100kg

    Product

    • Overview
    • Graphic
    • Technical
    • Configuration
    • Related

    Product

    • Overview
    • Graphic
    • Technical
    • Configuration
    • Related
    • Product Overview

      Mitech JMHVS-1-XYZ automatic precision micro hardness tester,based on the mechanical principle of the positive quadrilateral pyramid diamond indenter into the sample surface to produce indentation.By measuring the diagonal length of the indentation to achieve the hardness of the material.It is designed for small specimens,thick workpiece, heat treatment of the workpiece surface (infiltration coating) Vickers hardness test.With high automation degree,accurate measurement, integrated electromechanical integration in one,and the use of photoelectric sensor system to high magnification optical measurement,it is equipped with automatic turret device,high sensitivity touch screen operation interface to achieve automatic loading and unloading,automatic indentation marks,micro-auto focus measurement indentation diameter,GB/ASTM hardness automatic conversion, automatic test report and other functions.With the function of easy to operate and high efficiency,it is widely used in metal processing,electronics industry,mold parts,watches and clocks manufacturing,engineering quality inspection,and other fields,scientific research institutions etc.and it is the ideal hardness test equipment for sophisticated manufacturing and quality inspection departments to test materials.

      Function & application

      Working Principle

      The testing principle of Micro Vickers (or Knoop) hardness is the using of regular four-pyramid diamond pressure head, the selected fixed experimental force (load) is pressed into the specimen surface and maintained for a certain length of time (Paula), and then the experimental force (unloading) is removed.A positive pyramid or Knup indentation with a square on the surface of the specimen remains.The length of the diagonal is measured by the micrometer (0.020~1.400mm) to obtain the area of the indentation and to obtain the corresponding Vickers (or Knoop) hardness value.

      Usually Vickers hardness values can be converted according to the following formula:

      HV = constant × test force / indentation surface area ≈0.1891 F / d2;

      Note: HV: Vickers hardness symbol; F: test force (N); d: the arithmetic mean of indentation two diagonal d1, d2.

      Working Conditions

       Operating temperature: 18℃~28℃;

       Relative Humidity: ≤65%;

       In the absence of vibration, no corrosive media around the environment;

       Install horizontally on a solid basis.

      Instrument Features

      Operating Method and Attentions

      Instrument Maintenance

      Read the manual carefully before using the instrument. Learn the operation steps and attentions to avoid damage the instrument or personal safety accidents caused by improper operation; 

      When handling the instrument, it should be carried at the bottom of the machine, and it is forbidden to fall. Please remove the power plug before handling, fix the measuring lever and remove the weight and boom;

      When installing and commissioning the instrument, please carefully tear off the shockproof tape for protecting the indenter. If the force is excessive, it will cause the indenter to be accurate.

      The surface of the test piece should be smooth, no dirt, scale, pits and significant processing traces;

      When the instrument is used to remove the test force, it is forbidden to turn the handwheel. If the force is rotated, it will cause the internal gear to be dislocated, the test force will be disoriented, and even the damage to the parts inside the machine.

      Diamond indenter and indenter shaft are the core of the instrument, in the operation, be careful.Don’t touch the pressure head;

      To ensure the accuracy of the test, the pressure should be kept clean when used, such as indentation of oil or dust and other stains,it can be used with absorbent cotton (industrial) or wipe carefully ether at the top of the indenter;

      If you don’t use the tester for a long time,it should be covered with dust cover, so as not to dust into the machine.After using the hardness of the block and the ball head, it should be injected into anti-rust oil to prevent rust;

      Re-enable the device after a long time idle, wait a few minutes to make the internal electrical components of the instrument preheated and then test it to ensure the use of precision;

      Conducted at least once a year instrument verification, to ensure the accuracy of the hardness tester;

      Cut off the power supply first when you replace the fuse or remove weight ;

      Do not disassemble the instrument.Any related matters of repair, please contact the Department of Mitech Instrument Services, 4000600280.

    • Initially test force 10gf (0.098N)、25gf (0.246N)、50gf (0.49N)、100gf (0.98N)、 200gf (1.96N)、300gf (2.94N)、500gf (4.9N)、1k
      Measuring range 5-2500HV
      Hardness mode HV、HK
      Conversion scale HRA、HRB、HRC、HRD、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HV、HK、HBW
      Applying way of test force Automatic (plus, loading, unloading)
      Magnification of measuring microscope 100X(Observation) 400X(Measurement)
      The conversion mode of the lens’ head Automatic
      Minimum resolution 0.01μm
      Maximum height of applicable materials 210mm
      Maximum distance from head to the fuselage 320mm
      Display characteristics LCD large screen Display
      Test force holding time 0~60s
      Image focus Manual operation or automatic operation
      Camera (Pixel) 1.3 million
      Indentation measurement Manual operation or automatic operation
      Data statistics Automatically calculate the hardness of the average, variance, Cp, Cpk and other statistical values.
      Data storage Raw measurement data, images, etc.which can be saved in the document.
      Hardening curve Automatically draw the hardening curve
      Suitable for material edge scan Automatic (automatically scans along the edges of the test pieces and draws the edge overall diagram
      XYZ Sample Table 110mm*110mm
      Mobile control Manual operation or automatic operation
      Test report Automatically generate Word or Excel document reports in a format that can be customized (standard f
      Power supply AC220V±5%,50~60Hz
      Kirschner Hardness It can be set to Vickers hardness measurement
      Overall dimensions 490*320*530mm
      Machine weight 45kg
    ×

    郵箱反饋

    如您在和我公司的交往中遇到問題,可通過以下方式和我們?nèi)〉寐?lián)系!
    您也可以撥打我們客戶服務(wù)熱線:400-0600-280

    *
    *

    MITECH CO. LTD

    TEL :

    86-10-58859527
    008613810243516

    ADD:

    E-506, 1# of ShangDi East Road, Haidian District, Beijing, China

    Email: 

    mvip@mitech-ndt.com

    公眾號